Fridge repairs · 5 min read

The fridge is not cooling: the order to check it in

Power, airflow, defrost, thermostat, gas. Working through a domestic fridge in the right order finds the fault without guessing.

Start with the boring checks

Is the cabinet getting power, is the plug or circuit sound, and is the compressor actually running? A fridge that is silent may have a failed start relay or a tripped circuit rather than a gas problem, and those are quick to identify.

Then check airflow. A condenser packed with dust, a fan blade obstructed, or a cabinet pushed hard against a wall will all cause poor cooling with a perfectly healthy refrigeration circuit.

Defrost faults masquerade as gas faults

On a frost-free cabinet, a failed heater, sensor or timer leaves frost on the evaporator. Airflow drops, the fridge section warms while the freezer still feels cold, and the symptom looks like a slow refrigerant leak.

The giveaway is usually ice at the back panel or a cabinet that recovers after being switched off for a day. If it improves after a defrost, the circuit is probably fine and the defrost system is the fault.

Only then suspect the charge

Refrigerant does not get used up. If the charge is low, it has leaked, and recharging without finding the leak just postpones the same failure. A proper diagnosis includes locating it.

That matters for the economics too. A leak repair on an older cabinet is sometimes worth it and sometimes not, and the honest answer depends on the cabinet's age, insulation and replacement cost rather than on the repair price alone.