The void is the whole project
A ducted system needs a continuous path above the ceiling for a trunk and its branches, plus room for the indoor unit itself. In the Victorian and Edwardian houses across Claremont, Rondebosch and Observatory, that space is often 300 to 500 mm deep, crossed by beams and occupied by a geyser platform and decades of wiring.
Where the void is shallow, ducts can still be run if they are sized properly, but squeezing a large duct into a small space raises the air velocity. The result is a system that whistles at the grilles and loses capacity at the far end, which is why the survey has to happen before anyone quotes.
What can and cannot be cut
Pressed ceilings and moulded cornices are the usual constraint. Grille openings and inspection hatches can normally be planned onto plain ceiling board, but cutting through a decorative panel or a cornice run is a different decision and sometimes a heritage one.
The other constraint is the condensate. Water has to leave the ceiling with a continuous fall to a safe discharge point, and in an old house that often means a new route through a wall rather than reuse of whatever the original builder did.
When splits are the honest answer
If the void is discontinuous, the ceiling is protected, or only two or three rooms are ever used at once, high-wall or cassette units in those rooms will deliver comfort for less money and less disruption. A ducted system serving a whole house that is mostly empty is an expensive way to cool a passage.
We would rather propose the smaller, less impressive installation that works than a ducted system the building cannot support. The survey settles it, and it is worth doing before you fall in love with a grille detail.